SCTE

85.2.14.1 Configuration


SCTE Cue Tone

Parameter - Enable this plug-in feature
Description : Enable this checkbox to activate the plug-in feature.
Parameter - SCTE Inserter Main
Description : Provide the IP address and port number of Main SCTE inserter for sending cue tone to MUX server.
Parameter - SCTE Inserter Backup
Description : If there is Backup inserter configured, specify the IP address of Backup Inserter and port number to be used for sending cue tone to MUX server when the Main Inserter failed to do so.
Parameter - SCTE Inserter Timeout
Description : The timeout period during which the system awaits responses for previously issued SCTE commands before treating those commands as not received.

Then, 3 sections are available, one for each available command in the secondary events schedule:

Break Marking

Provider Placement Opportunity

Splice Insert

Parameters are the same for all 3 sections:
Parameter - Pid Index
Description : Set the index of the package identifier.
Parameter - AS Index
Description : Set the AS index as for device configuration.

If you have 2 SCTE Inserters, you can define the IP address for Backup inserter, or leave the Backup address as blank to setup as active-passive mode.  In active-passive mode, only the Main inserter would send commands, while the Backup inserter remain in standby mode.

NBSCTE104 has been implemented for Harmonic and Xvp-3901

SCTE